Differences in the Bisection Line in the Improved Neubauer Counting Booth on the Appropriateness of Leukocyte Count

  • Zidan Pramudya Sastra Poltekkes Kemenkes Jakarta 3
  • Eva Ayu Maharani
  • Dewi Astuti

Abstract

Leukocyte count examination is an examination that is often performed in clinical laboratories. Leukocyte count examination can be performed using a hematology analyzer or counting chamber for manual methods. Leukocyte cell counting using the manual method must use a standardized counting chamber. Currently, a different type of Improved Neubauer counting chamber variation has been found from the standard type, namely the difference in the outer limit of the counting area. In the standard type counting chamber, the outer limit of the counting area has three lines, while in the variation type counting chamber there is only one line. The purpose of this study was to determine whether there was a difference in the dividing line of the Improved Neubauer counting chamber on the suitability of the leukocyte count between the standard Improved Neubauer counting chamber type and the variation type Improved Neubauer counting chamber. The research design used in this study was observational analytic (Cross-Sectional) with a sample size of 20 EDTA blood. The results of the study obtained normally distributed data. then the Dependent Parametric Test (Paired T-Test) was carried out with a confidence level of 95%. The results of the Paired T-test showed the Sig.(2-tailed) value was 0.000 (<0.05). The conclusion of the study was that there was a significant difference in the results of the leukocyte count between the use of the standard Improved Neubauer counting chamber and the variation Improved Neubauer counting chamber. The use of the standard Improved Neubauer counting chamber is more recommended than the variation Improved Neubauer counting chamber.

References

Dosen Teknologi Laboratorium Medik Indonesia. HEMATOLOGI: Teknologi Laboratorium Medik. Ayu Maharani E, editor. Jakarta: EGC; 2021. xvii–341.
Risky novia rahayu. Gambaran Hitung Julah Leukosit Dan Immature/Total Neutrophil Ratio (I/T Ratio) Pada Neonatus Diduga Sepsis Di RSUD Dr Chasbullah Abdulmadjid Kota; 2019
Amaniyah Muti K. Perbedaan Penggunaan Antikoagulan NaEDTA, K2EDTA Dan K3EDTA Terhadap Profil Leukosit Yang Diperiksa Dengan Hematology Analyzer. 2021
Ariyadi T, Sukeksi A. Perbedaan Jumlah Lekosit Sampel Segera Diperiksa Dan Tunda 2 Jam Dan 4 jam Pada Pasien Lekositosis [Internet]. Available from: http://repository.unimus.ac.id. 2018.
Nur M, Harjoko A, Candradewi I. Klasifikasi Sel Darah Putih Berdasarkan Ciri Warna dan Bentuk dengan Metode K-Nearest Neighbor (K-NN). Vol.6, No.2, pp. 151~162; 2016.
Labmart. Counting Chamber for Hemacytometer, Germany (not medical device, only for professional lab use) [Internet]. Labmart. 2024 [cited 2024 May 1]. Available from: https://mylabmart.com/shop/counting-chamber-for-hemacytometer
Asiyah, Nur. Perbedaan Jumlah Leukosit Sampel Segera Diperiksa Dan Tunda 2 Jam Dan 4 Jam Pada Pasien Leukositosis. Manuscript.2018
dr.Fadli R. Tes Hematologi Rutin [Internet]. halodoc. 2022. [cited 2024 May 1]. Available from: https://www.halodoc.com/kesehatan/tes-hematologi-rutin
Iverson BL, Dervan PB. Hemostasis. 2018;7823–30.
Ayu Eva Maharani, Astuti Dewi. Buku Penuntun Praktikum Hematologi I Bagi Mahasiswa DIV. Modul.2016
Sugiyono. METLIT SUGIYONO.pdf. 2015. p. 3361.
Astuti Dewi, Ayu Eva Maharani. Buku Penuntun Praktikum Hematologi III Bagi Mahasiswa DIV. Modul.2018
Ahmad, Hanifa. Hubungan Hitung Neutrofil Dan Limfosit Terhadap Keparahan Penyakit Pada Pasien Covid-19 Di Rumah Sakit X Di Jawa Barat. Skirpsi. 2021
Raflanda, Hamidah. Perbandingan Hasil Hitung Jenis Leukosit Metode Manual Dengan Metode Otomatisasi Flowsitometri. Skirpsi. 2019
Notoatmodjo S. Metodologi penelitian kesehatan (2018) [Internet]. perpustakaan terpadu polkestama.2018p.243. [cited 2024 May 1]. Available from:http://opac.poltekkestasikmalaya.ac.id/index.php?p=show_detail&id=3190
Mushlih M, Rosyadi R. Buku Ajar Mata Kuliah Statistika “Aplikasi di Dunia Kesehatan”. Universitas Muhammmadiyah Sidoarjo 2020. Sidoarjo. UMSIDA Press; 2020
Sopiyudin M Dahlan. Besar Sampel Dan Cara Pengambilan Sampel Dalam Penelitian Kedokteran dan Kesehatan. Edisi 3 seri evidence based medicine 2. Jakarta. 2018
Zhang M, Lingui Gu, Zheng Peihua, Chen Zhixin, Dou Xinqi, qin Qizhong. Improvement Of Cell Counting Method For Neubauer Counting Chamber. [Internet]. Journal of Clinical laboratory Analysis/Volume 34, Issue 1/e23024 [cited 2024 june 26]. Available from: https://onlinelibrary.wiley.com/doi/10.1002/jcla.23024
Published
2024-12-05
How to Cite
Sastra, Z., Maharani, E., & Astuti, D. (2024). Differences in the Bisection Line in the Improved Neubauer Counting Booth on the Appropriateness of Leukocyte Count. Jurnal Fisioterapi Dan Kesehatan Indonesia, 4(02), 315-321. https://doi.org/10.59946/jfki.2024.369